Equipment failure 1. The fabric is tilted, and “bite” occurs when the cloth inspection machine is moving forward: This is mainly caused by the non-parallel cloth guide rollers of the cloth inspection machine. The equipment operator only needs to adjust the parallelism of the cloth guide rollers. solve. the
Equipment failure 2. Irregular cloth roll: The irregular cloth roll is caused by the unevenness of the cloth roll and guide roller, so adjusting the parallelism between the cloth roll and guide roll can completely eliminate the problem of uneven roll. the
Equipment failure 3. The cloth inspection machine guides and rolls heavy: the cause of this problem may be that the transmission part of the machine has dust, cloth wool and oil stains, or the transmission parts are not installed properly, as long as we install the cloth inspection machine correctly It is enough to clean the transmission parts and regularly clean the oil and cloth in the machine.REHOW provides textile industrial machines to the whole world, helping them improve efficiency and reduce labor cost. ReHow provides various types of textile machinery: raising machine, cloth inspection machine, packing machine, coiling machine, slitting machine, cross cutting machine, ribbon weaving machine, weaving machine, etc. If you are interested in us, please contact us now!