Maintenance of slitting machine equipment

Slitting machine equipment maintenance
(1) The operator of the slitting machine should understand the function and performance of the equipment, master the correct method of use, assign personnel and posts, and follow the cross-operation method of “cleaning, lubricating, fastening, debugging, and anti-corrosion” for minimum maintenance in each shift once.
(2) The contact surface of each slider of the slitting machine should be cleaned and refueled frequently to prevent damage to the sliding surface. The four sliders on the moving beam should be cleaned when disassembling and assembling. The lifting knife can only be moved after spraying hydraulic oil with an oil pot. , to prevent the reduction of the precision of the slitting machine caused by the burning of the sliding surface.
(3) The air filter of the DC motor fan should be replaced at least once every 3 days to ensure that the DC motor is well ventilated to prevent damage to the slitting machine motor due to temperature rise during operation.
(4) The pressure of the hydraulic pump station is not allowed to be adjusted at will. If the slitting machine fails, it should be repaired by the maintenance worker. The working pressure of the hydraulic pump station is controlled within 14MPa.

 


Post time: Jan-05-2023